The APS 3000 Series
frequency and voltage converters are economically priced and
offer top of the line performance.
The series consists of seven 3 phase output instruments ranging in size
from 3 kVA to 90 kVA. The converters allow
the user to duplicate a utility grid of either 50 or 60 hertz for export
product testing or operation of imported equipment.
The frequency can be adjusted to 400 hertz for applications
such as the testing of military/avionics equipment or for
the operation of 400 hertz electronics that are onboard an
aircraft or a military vessel. The adjustable
frequency band of 45 to 500 Hertz in conjunction with the
dual voltage ranges of 0-150 volts or 0-300 volts provides
full capabilities for testing and operating electronics
worldwide.
Setup and operation of the APS 3000 Series is exceptionally
easy. The simple front panel layout allows users to
continuously vary voltage and frequency or to select preset
standard frequency settings. Individual meter displays
provide digital readouts for frequency, voltage and current
while a digital multimeter displays power or power factor.
The APS 3000 series converters are a simple and cost
effective solution for all of your AC power conversion
needs!
| Key
Features & Specifications for the APS 3000 Series |
 |
Output
Power: |
3 kVA to 90 kVA |
 |
Output
Frequency: |
45-500
Hz |
 |
Output Voltage: |
Dual
range, 150-260 V or 300-520 V, 3 phase |
 |
Isolated Linear Output, THD: |
< 1% |
 |
Input
Requirements: |
220, 240, 380, 415, 480 VAC
±
10%, 3 phase, 47 - 63 Hz |
 |
Intuitive Front Panel Controls: |
Frequency and Voltage |
 |
Easy
to Read LED Displays: |
Frequency,
Voltage, Current, Power and Power Factor |
 |
Memory Locations: |
Can save three desired settings of any voltage,
frequency and current limit covered in the output
parameters |
|
 |
| Model |
3003
|
3006
|
3009
|
3015
|
3030
|
3060
|
3090
|
|
INPUT SPECIFICATIONS |
|
Phase |
1Ø/2W + ground |
3Ø/3W + ground |
|
Voltage |
230V ± 15% |
220, 240, 380, 415, 480V ± 10% |
|
Frequency |
47 - 63 Hz |
|
OUTPUT SPECIFICATIONS |
| Power Rating
(Total Power) |
3kVA |
6kVA |
9kVA |
15kVA |
30kVA |
60kVA |
90kVA |
| Power Rating
(Per Phase) |
1kVA |
2kVA |
3kVA |
5kVA |
10kVA |
20kVA |
30kVA |
| Max Arms
per Ø @ 0-150 V |
8.4A |
16.8A |
25.2A |
42.0A |
84.0A |
168.0A |
252.0A |
| Max Arms
per Ø @ 0-300 V |
4.2A |
8.4A |
12.6A |
21.0A |
42.0A |
84.0A |
126.0A |
|
Phase |
3Ø/5W |
|
Line to Neutral Voltage |
0-150V / 0-300V Selectable |
|
Line to Line Voltage |
0-260V / 0-520V Selectable |
|
Voltage Resolution |
0.1V |
|
Voltage Accuracy |
± (1% + 0.2V) |
|
Frequency Range |
45-500 Hz |
|
Frequency Resolution |
0.1Hz at 45-99.9Hz, 1Hz at 100-500Hz |
|
Frequency Accuracy |
± 0.2% |
|
Harmonic Distortion |
≤
1% (Resistance Load) |
|
Crest Factor |
≥
3 to 1 |
|
Load Regulation |
± 0.5% |
|
Protection |
Over Current, Short Circuit, Over Temperature |
|
Efficiency |
≥
85% (at full load) |
|
Operating Temperature |
32˚-104˚F, (0˚-40˚C), 80% Relative Humidity |
|
Altitude |
below 6500 feet |
|
DISPLAYS AND CONTROLS |
|
4 Digital LED meters |
Frequency, voltage, Current, Power or Power Factor
(simultaneously) |
|
PLC Remote Interface |
P1, P2, P3 and Output On/Off |
|
Memory |
3 Programmable Memory Locations for voltage, Frequency
and Current |
|
Calibration |
Front Panel Calibration |
|
Interface (optional) |
GPIB or RS-232 |
|
Auto voltage adjust |
Enabled for improved voltage regulation within
± 0.1% |
|
MECHANICAL SPECIFICATIONS |
|
Dimensions
(HxDxW) Inches |
34x26x17 |
32x36x24 |
38x36x24 |
55x36x24 |
TBD |
|
Weights (Kg/lbs) |
140/305 |
175/385 |
220/485 |
290/640 |
460/1010 |
760/1675 |
1200/2640 |
|