New low-cost frequency converters allow users
to simulate world-wide power for export product testing and
duplication of military/avionics power for 400 Hz aircraft
or shipboard use.
The
FC 100 Series frequency and voltage converters are economically
priced and offer top of the line performance. The series consists
of four instruments ranging in size from 500 VA to 3 kVA.
The converters allow the user to duplicate a utility grid
of either 50 or 60 hertz for export product testing or operation
of imported equipment.
The
frequency can be adjusted to 400 hertz for applications such
as the testing of military/avionics equipment or for the operation
of 400 hertz electronics that are onboard an aircraft or a
military vessel. The adjustable frequency band of 45 to 500
Hertz in conjunction with the dual voltage ranges of 0-150
volts or 0-300 volts provides full capabilities for testing
and operating electronics worldwide.
Setup
and operation of the FC 100 Series is exceptionally easy.
The simple front panel layout allows users to continuously
vary voltage and frequency or to select preset standard frequency
settings. Universal power outlets are provided on the front
panel for ready access to the controlled power. Individual
meter displays provide digital readouts for frequency and
voltage while a digital multimeter displays current, power
or power factor.
The
FC 100 Series converters are a simple and cost effective solution
for all of your AC power conversion needs!
| Key
Features & Specifications for the FC 100 Series |
 |
Output
Power: |
500
VA to 3,000 VA |
 |
Output
Frequency: |
45-500
Hz |
 |
Output Voltage: |
Dual
range, 0-150 V or 0-300 V, 1 phase |
 |
Isolated Linear Output, THD: |
0.5% |
 |
Input
Requirements: |
115 VAC or 230 VAC, 1 phase, 47-63 Hz |
 |
Intuitive Front Panel Controls: |
Frequency and Voltage |
 |
Easy
to Read LED Displays: |
Frequency,
Voltage, Current, Power and Power Factor |
 |
Power
Outlets: |
Universal
Domestic and International Connectors |


| Model |
FC105
|
FC110
|
FC120
|
FC130
|
| Output
Power |
|
500
VA
|
1
kVA
|
2
kVA
|
3
kVA
|
| Output
Voltage |
0-300
VAC @ 0.1V per step
|
| Output
Current (rms) |
0-150
V |
4.2
A
|
8.4
A
|
16.8
A
|
25.0 A
|
| 0-300
V |
2.1
A
|
4.2 A
|
8.4
A
|
12.5 A
|
| Frequency |
45
- 500 Hz
|
| Waveform |
Sine
Wave, 0.5% THD (Resistive Load)
|
| Line
Regulation |
±
0.1 V
|
| Load
Regulation |
±
0.5%, 100 µs Recovery Time
|
| Protection |
Key
Lock, OCP, Short
|
| Calibration |
Built
in software for front panel calibration
|
| Input
Voltage |
|
115/230
VAC ±10%, 47 - 63 Hz, Single Phase |
230
VAC ±10%, 47 - 63 Hz, Single Phase |
| Operating
Environment |
32°
- 104°F / 80% RH
0° - 40°C / 80% RH
|
| Dimensions
(H/W/D) |
(in)
|
5.25/17/19.7
|
8.75/17/20.5
|
10.5/17/21.7
|
18.3/17/25.6
|
|
(mm)
|
3U/432/500
|
5U/432/520
|
267/432/550
|
465/432/650
|
| Weight |
(lbs.)
|
55
|
77
|
132
|
308
|
|
(kg.)
|
25
|
35
|
60
|
138
|
| MEASUREMENT |
RANGE
|
RESOLUTION
|
ACCURACY
|
| Frequency |
0.0
- 500.0 Hz
|
0.1
Hz / Step
|
±
0.2 Hz
|
| Voltage |
0.0
- 300.0 VAC
|
0.1
V / Step
|
±
(1% of Reading + 1 Count)
|
| Current |
0.000
- 2.000 A
|
1
mA
|
±
(1% of Reading + 5 Counts)
|
|
1.80
- 35.00 A
|
0.01
A
|
±
(1% of Reading + 2 Counts)
|
| Power |
0.0
- 360.0 W
|
0.1
W
|
±
(1.5% of Reading + 5 Counts)
|
|
320
- 3500 W
|
1 W
|
±
(1.5% of Reading + 1 Count)
|
| Power
Factor |
0.000
- 1.000
|
0.001
|
±
(2% of Reading + 2 Counts)
|
|